Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2017-10724 : Exploit Details and Defense Strategies

Learn about CVE-2017-10724, a critical vulnerability in Shekar Endoscope's firmware allowing remote code execution. Find out how to mitigate risks and secure IoT devices.

A vulnerability in the Shekar Endoscope's firmware allows attackers connected to the device's Wi-Fi to execute remote code, potentially compromising sensitive data and gaining access to secure networks.

Understanding CVE-2017-10724

This CVE identifies a critical security flaw in the Shekar Endoscope, an IoT device used for industrial, automotive, and medical applications.

What is CVE-2017-10724?

The vulnerability in the Shekar Endoscope's firmware enables attackers to exploit a memory corruption issue, execute remote code, and potentially access sensitive information and control the device remotely.

The Impact of CVE-2017-10724

If exploited, this vulnerability allows attackers to breach the device's security, access video feeds and images, and potentially infiltrate air-gapped networks, especially critical infrastructure systems.

Technical Details of CVE-2017-10724

The technical aspects of the CVE-2017-10724 vulnerability are as follows:

Vulnerability Description

The vulnerability arises from a memory corruption issue in the Shekar Endoscope's firmware, allowing attackers to execute remote code by manipulating the device's Wi-Fi settings.

Affected Systems and Versions

        Product: Shekar Endoscope
        Vendor: Shekar
        Versions: All versions with the vulnerable firmware

Exploitation Mechanism

        Attackers connected to the device's Wi-Fi SSID can send a crafted UDP request to change the Wi-Fi name, triggering the vulnerability.
        By overflowing the "setwifipassword" function, attackers can manipulate the $PC value and execute remote code on the device.

Mitigation and Prevention

To mitigate the risks associated with CVE-2017-10724, consider the following steps:

Immediate Steps to Take

        Disable remote access to the Shekar Endoscope if not required.
        Implement strong Wi-Fi security measures, including changing default passwords.
        Regularly monitor network traffic for any suspicious activities.

Long-Term Security Practices

        Keep the device firmware up to date with the latest security patches.
        Conduct regular security audits and penetration testing on IoT devices.

Patching and Updates

        Check for firmware updates from the vendor and apply them promptly to address the vulnerability.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now