Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2017-6034 : Exploit Details and Defense Strategies

Discover the impact of CVE-2017-6034, an Authentication Bypass through Capture-Replay vulnerability in Schneider Electric Modicon Modbus Protocol. Learn about affected systems, exploitation risks, and mitigation strategies.

A security vulnerability known as an Authentication Bypass through Capture-Replay has been found in the Schneider Electric Modicon Modbus Protocol. This protocol transmits sensitive information without encryption, making it possible for a malicious actor to replicate and re-execute specific commands such as run, stop, upload, and download.

Understanding CVE-2017-6034

This CVE involves an Authentication Bypass through Capture-Replay vulnerability in the Schneider Electric Modicon Modbus Protocol.

What is CVE-2017-6034?

CVE-2017-6034 is an Authentication Bypass through Capture-Replay vulnerability in the Schneider Electric Modicon Modbus Protocol, allowing unauthorized access to sensitive information and the ability to replay critical commands.

The Impact of CVE-2017-6034

The vulnerability enables malicious actors to intercept and manipulate sensitive data transmitted without encryption, potentially leading to unauthorized command execution and control over affected systems.

Technical Details of CVE-2017-6034

This section provides detailed technical information about the CVE.

Vulnerability Description

The issue involves an Authentication Bypass through Capture-Replay in the Schneider Electric Modicon Modbus Protocol, allowing attackers to replicate and re-execute specific commands.

Affected Systems and Versions

        Product: Schneider Electric Modicon Modbus Protocol
        Version: Schneider Electric Modicon Modbus Protocol

Exploitation Mechanism

The vulnerability arises due to the lack of encryption in the Modbus protocol, enabling threat actors to capture and replay critical commands like run, stop, upload, and download.

Mitigation and Prevention

Protecting systems from CVE-2017-6034 requires immediate actions and long-term security practices.

Immediate Steps to Take

        Implement network segmentation to isolate critical systems from potential attacks.
        Monitor network traffic for any suspicious activities or unauthorized access attempts.
        Apply encryption mechanisms to secure sensitive data transmissions.

Long-Term Security Practices

        Regularly update and patch the affected systems to address known vulnerabilities.
        Conduct security assessments and penetration testing to identify and remediate weaknesses.
        Educate personnel on cybersecurity best practices to enhance overall awareness and response capabilities.

Patching and Updates

        Stay informed about security advisories and patches released by Schneider Electric for the Modicon Modbus Protocol.
        Apply recommended updates promptly to mitigate the risk of exploitation.