Discover the impact of CVE-2018-11451, affecting Siemens AG firmware variants and relay devices. Learn about the exploitation mechanism, affected systems, and mitigation steps.
A security vulnerability has been discovered in various firmware variants, including IEC 61850, PROFINET IO, Modbus TCP, DNP3 TCP, and IEC104, for the EN100 Ethernet module. This vulnerability affects all versions prior to V4.33 for IEC 61850, all versions for PROFINET IO and Modbus TCP, and all versions prior to V1.22 for IEC104. It also affects SIPROTEC 5 relays with CPU variants CP300 and CP100, as well as their respective Ethernet communication modules, all versions prior to V7.80. Additionally, it affects SIPROTEC 5 relays with CPU variants CP200 and their respective Ethernet communication modules, all versions prior to V7.58. Exploiting this vulnerability involves sending specially crafted packets to port 102/tcp, which can lead to a denial-of-service situation in the affected products. To restore the functionality of the EN100 module in the affected devices, a manual restart is required. Successful exploitation requires an attacker to have network access and send multiple packets to the affected products or modules. The IEC 61850-MMS communication must be activated on the affected products or modules as a precondition for the vulnerability to be exploited. No user interaction or privileges are necessary to exploit this vulnerability. If successfully exploited, the vulnerability can compromise the availability of the system by causing a Denial-of-Service condition in the network functionality of the affected device. As of the publication of this advisory, there have been no known instances of public exploitation of this security vulnerability.
Understanding CVE-2018-11451
This CVE-2018-11451 vulnerability affects various firmware variants and SIPROTEC 5 relays with specific CPU variants and Ethernet communication modules.
What is CVE-2018-11451?
CVE-2018-11451 is a security vulnerability found in multiple firmware variants and relay devices manufactured by Siemens AG.
The Impact of CVE-2018-11451
Technical Details of CVE-2018-11451
This section provides detailed technical information about the vulnerability.
Vulnerability Description
The vulnerability allows attackers to cause a denial-of-service condition by sending specially crafted packets to port 102/tcp.
Affected Systems and Versions
Exploitation Mechanism
Mitigation and Prevention
Protecting systems from CVE-2018-11451 requires immediate actions and long-term security practices.
Immediate Steps to Take
Long-Term Security Practices
Patching and Updates