CVE-2018-19009 : Exploit Details and Defense Strategies

Learn about CVE-2018-19009 affecting Pilz PNOZmulti Configurator software. Find out how authenticated attackers can access sensitive data and how to mitigate this security risk.

The Pilz PNOZmulti Configurator software, prior to version 10.9, contains a security vulnerability that allows authenticated attackers with local access to view sensitive credential information in plain text.

Understanding CVE-2018-19009

This CVE entry highlights a vulnerability in the Pilz PNOZmulti Configurator software that can lead to unauthorized access to sensitive data.

What is CVE-2018-19009?

The CVE-2018-19009 vulnerability in the Pilz PNOZmulti Configurator software allows authenticated attackers with local access to view sensitive credential information in clear text. This issue specifically impacts the PMI m107 diag HMI device.

The Impact of CVE-2018-19009

The vulnerability enables attackers to access and potentially modify sensitive data on the PMI m107 diag HMI device, posing a risk of unauthorized data manipulation.

Technical Details of CVE-2018-19009

This section delves into the technical aspects of the CVE-2018-19009 vulnerability.

Vulnerability Description

The Pilz PNOZmulti Configurator software, versions prior to 10.9, allows authenticated attackers with local access to view sensitive credential information in plain text.

Affected Systems and Versions

        Product: Pilz PNOZmulti Configurator
        Vendor: Pilz
        Affected Versions: All versions prior to version 10.9

Exploitation Mechanism

The vulnerability can be exploited by authenticated attackers with local access to the system containing the PNOZmulti Configurator software, specifically impacting the PMI m107 diag HMI device.

Mitigation and Prevention

Protecting systems from CVE-2018-19009 requires immediate actions and long-term security practices.

Immediate Steps to Take

        Update the Pilz PNOZmulti Configurator software to version 10.9 or newer.
        Restrict physical access to the PMI m107 diag HMI device to authorized personnel only.

Long-Term Security Practices

        Implement strong access controls and authentication mechanisms.
        Regularly monitor and audit access to sensitive systems and data.

Patching and Updates

        Stay informed about security updates and patches released by Pilz.
        Apply patches promptly to ensure system security.