Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2018-7762 : Vulnerability Insights and Analysis

Discover the critical vulnerability in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200, allowing a buffer overflow risk through web service's SOAP request processing. Learn about the impact, affected systems, and mitigation steps.

Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 are vulnerable to a buffer overflow through their web service's SOAP request processing.

Understanding CVE-2018-7762

This CVE involves a critical vulnerability in Schneider Electric's industrial control systems.

What is CVE-2018-7762?

The vulnerability in the web services of Schneider Electric's PLCs could lead to a buffer overflow, potentially allowing attackers to exploit the system.

The Impact of CVE-2018-7762

The vulnerability poses a significant risk of buffer overflow, which could be exploited by malicious actors to compromise the affected systems.

Technical Details of CVE-2018-7762

Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 are affected by this vulnerability.

Vulnerability Description

The flaw lies in the SOAP request processing of the web services, creating a buffer overflow risk.

Affected Systems and Versions

        Product: Modicon M340, Modicon Premium, Modicon Quantum, BMXNOR0203
        Vendor: Schneider Electric SE
        Versions: All Modicon M340, Premium, Quantum PLCs and BMXNOR0203

Exploitation Mechanism

The vulnerability can be exploited through malicious SOAP requests, potentially leading to a buffer overflow.

Mitigation and Prevention

Immediate Steps to Take:

        Apply security patches provided by Schneider Electric.
        Implement network segmentation to limit exposure.
        Monitor network traffic for any suspicious activity.

Long-Term Security Practices:

        Regularly update and patch industrial control systems.
        Conduct security assessments and penetration testing.
        Educate staff on cybersecurity best practices.
        Implement strong access controls and authentication mechanisms.
        Consider network intrusion detection systems.
        Stay informed about cybersecurity threats and vulnerabilities.

Patching and Updates:

        Stay informed about security advisories from Schneider Electric.
        Apply patches promptly to mitigate the risk of exploitation.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now