CVE-2019-14709 : Exploit Details and Defense Strategies

Discover the security issue on MicroDigital N-series cameras with firmware up to 6400.0.8.5. Learn how attackers can exploit plain text passwords and how to mitigate the CVE-2019-14709 vulnerability.

An issue related to the storage of passwords in plain text has been found on MicroDigital N-series cameras with firmware versions up to 6400.0.8.5. The vulnerable file is located at /usr/local/ipsca/mipsca.db. In the event of a camera being compromised, an attacker can obtain the passwords and exploit them to compromise other systems.

Understanding CVE-2019-14709

A cleartext password storage issue was discovered on MicroDigital N-series cameras with firmware through 6400.0.8.5. If a camera is compromised, the attacker can gain access to passwords and abuse them to compromise further systems.

What is CVE-2019-14709?

        Vulnerability related to storing passwords in plain text on MicroDigital N-series cameras
        Cameras with firmware versions up to 6400.0.8.5 are affected
        The vulnerable file is mipsca.db located at /usr/local/ipsca

The Impact of CVE-2019-14709

        Attackers can access passwords stored in plain text
        Compromised passwords can be used to exploit other systems

Technical Details of CVE-2019-14709

A cleartext password storage vulnerability affecting MicroDigital N-series cameras with specific firmware versions.

Vulnerability Description

        Issue with storing passwords in plain text on MicroDigital N-series cameras
        Vulnerable file: /usr/local/ipsca/mipsca.db

Affected Systems and Versions

        MicroDigital N-series cameras with firmware up to 6400.0.8.5

Exploitation Mechanism

        Attackers can compromise a camera to access stored passwords
        Exploited passwords can be used to compromise additional systems

Mitigation and Prevention

Steps to address and prevent the CVE-2019-14709 vulnerability.

Immediate Steps to Take

        Update camera firmware to a secure version
        Change all passwords stored on affected cameras
        Monitor for any unauthorized access or unusual activity

Long-Term Security Practices

        Implement strong password policies and encryption practices
        Regularly update firmware and security patches for cameras
        Conduct security audits and penetration testing

Patching and Updates

        Apply patches provided by MicroDigital for the affected cameras
        Stay informed about security updates and advisories from the vendor

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now