Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2019-18310 : What You Need to Know

Learn about CVE-2019-18310, a vulnerability in Siemens SPPA-T3000 MS3000 Migration Server allowing attackers to trigger a Denial-of-Service situation. Find out how to mitigate and prevent exploitation.

A security flaw has been detected in the SPPA-T3000 MS3000 Migration Server by Siemens, allowing attackers to trigger a Denial-of-Service situation.

Understanding CVE-2019-18310

This CVE identifies a vulnerability in the SPPA-T3000 MS3000 Migration Server that can be exploited by attackers with network access.

What is CVE-2019-18310?

The CVE-2019-18310 vulnerability allows attackers to cause a Denial-of-Service scenario by sending specially crafted packets to port 7061/tcp on the MS3000 Server.

The Impact of CVE-2019-18310

        Attackers can exploit this vulnerability to disrupt the availability of the MS3000 Server through network-based attacks.
        The flaw is distinct from CVE-2019-18311 and requires network access to the MS3000 Server for exploitation.
        No public instances of exploitation have been reported at the time of the advisory publication.

Technical Details of CVE-2019-18310

This section provides detailed technical information about the vulnerability.

Vulnerability Description

        Type: CWE-121: Stack-based Buffer Overflow
        Description: The vulnerability allows for a Denial-of-Service condition on the MS3000 Server.

Affected Systems and Versions

        Product: SPPA-T3000 MS3000 Migration Server
        Vendor: Siemens
        Affected Versions: All versions

Exploitation Mechanism

        Attackers exploit the vulnerability by sending specially crafted packets to port 7061/tcp on the MS3000 Server.

Mitigation and Prevention

Protecting systems from CVE-2019-18310 requires immediate actions and long-term security practices.

Immediate Steps to Take

        Monitor network traffic for any suspicious activity targeting port 7061/tcp.
        Implement firewall rules to restrict access to the MS3000 Server.

Long-Term Security Practices

        Regularly update and patch the MS3000 Server to mitigate known vulnerabilities.
        Conduct security assessments and penetration testing to identify and address potential weaknesses.
        Educate staff on cybersecurity best practices to prevent unauthorized access.
        Stay informed about security advisories and updates from Siemens.
        Consider implementing network segmentation to limit the impact of potential attacks.

Patching and Updates

        Stay informed about security patches and updates released by Siemens for the SPPA-T3000 MS3000 Migration Server.