CVE-2019-6538 : Security Advisory and Response

Learn about CVE-2019-6538 affecting Medtronic devices. Attackers can manipulate telemetry communication, potentially impacting implanted cardiac devices. Find mitigation steps here.

CVE-2019-6538 was published on March 25, 2019, by Medtronic. The vulnerability affects various Medtronic devices utilizing the Conexus Radio Frequency Telemetry Protocol. Attackers with nearby access can manipulate data in telemetry communication, potentially impacting implanted cardiac devices.

Understanding CVE-2019-6538

This CVE highlights a lack of authentication and authorization in the Conexus telemetry protocol used in multiple Medtronic devices.

What is CVE-2019-6538?

The vulnerability allows attackers to inject, replay, modify, or intercept data in telemetry communication, enabling manipulation of memory values in implanted cardiac devices.

The Impact of CVE-2019-6538

The vulnerability poses a significant risk as attackers can exploit the communication protocol to alter memory within implanted cardiac devices, potentially leading to severe consequences.

Technical Details of CVE-2019-6538

The following technical details provide insight into the vulnerability.

Vulnerability Description

The Conexus telemetry protocol lacks proper authentication and authorization, allowing unauthorized manipulation of data in telemetry communication.

Affected Systems and Versions

The following Medtronic devices are affected:

        MyCareLink Monitor versions 24950 and 24952
        CareLink Monitor version 2490C
        CareLink 2090 Programmer
        Various CRT-D and ICD models

Exploitation Mechanism

Attackers with short-range access to affected devices can exploit the vulnerability when the product's radio is turned on, enabling data manipulation in telemetry communication.

Mitigation and Prevention

Protecting systems from CVE-2019-6538 is crucial to prevent potential exploitation.

Immediate Steps to Take

        Disable radio functionality when not in use
        Implement strong access controls
        Regularly monitor for unauthorized access

Long-Term Security Practices

        Conduct security assessments regularly
        Keep devices updated with the latest security patches

Patching and Updates

        Apply patches provided by Medtronic to address the vulnerability