Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2020-13859 : Exploit Details and Defense Strategies

Discover the security vulnerability in Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices allowing unauthorized access to the management interface. Learn about the impact, affected systems, exploitation, and mitigation steps.

An issue was discovered on Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices, allowing unauthorized access to the management interface.

Understanding CVE-2020-13859

This CVE identifies a security vulnerability in Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices that enables unauthorized access to the management interface.

What is CVE-2020-13859?

The vulnerability arises from a format error in /etc/shadow and a logic bug in the LuCI - OpenWrt Configuration Interface framework. It permits the undocumented system account 'mofidev' to log in to the management interface without a password by exploiting a forgotten-password feature.

The Impact of CVE-2020-13859

The vulnerability allows unauthorized users to access the management interface, potentially leading to unauthorized configuration changes, data theft, or further exploitation of the affected devices.

Technical Details of CVE-2020-13859

This section provides technical details about the vulnerability.

Vulnerability Description

The issue allows the 'mofidev' account to bypass authentication and gain access to the management interface without a password.

Affected Systems and Versions

        Mofi Network MOFI4500-4GXeLTE 4.0.8-std devices are affected by this vulnerability.

Exploitation Mechanism

        The vulnerability is exploited by abusing a forgotten-password feature, combined with a format error in /etc/shadow and a logic bug in the LuCI framework.

Mitigation and Prevention

Protect your systems from CVE-2020-13859 with the following steps:

Immediate Steps to Take

        Disable remote access to the management interface if not required.
        Change default passwords and ensure strong, unique passwords are set.
        Regularly monitor and review system logs for any unauthorized access attempts.

Long-Term Security Practices

        Implement network segmentation to restrict access to critical devices.
        Keep systems up to date with the latest security patches and firmware updates.

Patching and Updates

        Apply patches and updates provided by Mofi Network to address this vulnerability.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now