Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2020-25860 : What You Need to Know

Learn about CVE-2020-25860, a critical Time-of-Check Time-of-Use vulnerability in Pengutronix RAUC update client before version 1.5, enabling attackers to install arbitrary code on devices.

A Time-of-Check Time-of-Use vulnerability in Pengutronix RAUC update client before version 1.5 allows attackers to install arbitrary code on devices.

Understanding CVE-2020-25860

This CVE involves a critical security flaw in the Pengutronix RAUC update client that could lead to unauthorized code execution on affected devices.

What is CVE-2020-25860?

The vulnerability in the install.c module of Pengutronix RAUC allows an attacker to manipulate update files during the signature verification process, potentially leading to the installation of malicious code during the update process.

The Impact of CVE-2020-25860

Exploitation of this vulnerability could result in unauthorized access, data breaches, and the execution of arbitrary code on devices running vulnerable versions of Pengutronix RAUC.

Technical Details of CVE-2020-25860

This section provides more in-depth technical insights into the vulnerability.

Vulnerability Description

The Time-of-Check Time-of-Use vulnerability in Pengutronix RAUC update client allows attackers to modify update files during the signature verification process, enabling the installation of unauthorized code during updates.

Affected Systems and Versions

        Product: Pengutronix RAUC
        Vendor: n/a
        Versions Affected: All versions before 1.5

Exploitation Mechanism

Attackers can exploit this vulnerability by tampering with update files just before they are reopened for installation, bypassing signature verification and injecting malicious code onto the device.

Mitigation and Prevention

Protecting systems from CVE-2020-25860 requires immediate actions and long-term security measures.

Immediate Steps to Take

        Update Pengutronix RAUC to version 1.5 or newer to mitigate the vulnerability.
        Monitor for any suspicious activities on the device that could indicate exploitation of the flaw.

Long-Term Security Practices

        Implement secure update mechanisms that verify files at multiple stages to prevent Time-of-Check Time-of-Use vulnerabilities.
        Regularly audit and update firmware to address security issues and protect against emerging threats.

Patching and Updates

        Stay informed about security advisories and patches released by Pengutronix for RAUC to address known vulnerabilities and enhance system security.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now