Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2020-6789 : Exploit Details and Defense Strategies

Learn about CVE-2020-6789, a high-severity vulnerability in Bosch Monitor Wall installer allowing arbitrary code execution. Find mitigation steps and affected versions here.

A vulnerability in the Bosch Monitor Wall installer up to version 10.00.0164 allows attackers to execute arbitrary code on a victim's system by loading a DLL through an uncontrolled search path element.

Understanding CVE-2020-6789

This CVE involves a security issue in the Bosch Monitor Wall installer that could lead to the execution of arbitrary code on a victim's system.

What is CVE-2020-6789?

The vulnerability arises from the loading of a DLL through an uncontrolled search path element in the Bosch Monitor Wall installer, potentially enabling attackers to run malicious code on the victim's system.

The Impact of CVE-2020-6789

The vulnerability has a CVSS base score of 7.8, indicating a high severity level. It can result in high impacts on confidentiality, integrity, and availability of the affected system.

Technical Details of CVE-2020-6789

This section provides detailed technical information about the CVE.

Vulnerability Description

The flaw allows an attacker to execute arbitrary code on a victim's system by tricking them into placing a malicious DLL in the same directory where the Bosch Monitor Wall installer is launched.

Affected Systems and Versions

        Product: Monitor Wall
        Vendor: Bosch
        Versions Affected: <= 10.00.0164 (custom version)

Exploitation Mechanism

        Attack Complexity: Low
        Attack Vector: Local
        Privileges Required: None
        User Interaction: Required
        Scope: Unchanged
        Exploitation Impact: High

Mitigation and Prevention

Protecting systems from CVE-2020-6789 requires immediate actions and long-term security practices.

Immediate Steps to Take

        Avoid running the Bosch Monitor Wall installer from untrusted sources.
        Regularly update security software to detect and prevent such vulnerabilities.

Long-Term Security Practices

        Educate users about the risks of downloading and executing files from unknown sources.
        Implement strict file system access controls to prevent unauthorized DLL loading.

Patching and Updates

        Apply patches and updates provided by Bosch to address the vulnerability in the Monitor Wall installer.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now