Learn about CVE-2020-7477, a CWE-754 vulnerability in Schneider Electric's Modicon Quantum Ethernet Network module and Quantum / Premium COPRO, potentially leading to a Denial of Service attack. Find out how to mitigate and prevent this security risk.

A CWE-754 vulnerability exists in Schneider Electric's Modicon Quantum Ethernet Network module and Quantum / Premium COPRO, potentially leading to a Denial of Service attack.

Understanding CVE-2020-7477

This CVE involves an Improper Check for Unusual or Exceptional Conditions vulnerability in specific Schneider Electric products.

What is CVE-2020-7477?

The vulnerability affects the Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior), Quantum processors with integrated Ethernet, and Premium processors with integrated Ethernet. It could be exploited by sending a specially crafted command over Modbus, resulting in a Denial of Service.

The Impact of CVE-2020-7477

The vulnerability could allow attackers to disrupt the normal operation of affected devices, potentially leading to service unavailability or downtime.

Technical Details of CVE-2020-7477

This section provides more technical insights into the vulnerability.

Vulnerability Description

The CWE-754 vulnerability arises from an improper check for unusual or exceptional conditions in the affected Schneider Electric products.

Affected Systems and Versions

        Modicon Quantum Ethernet Network module 140NOE771x1 (Versions 7.0 and prior)
        Quantum processors with integrated Ethernet – 140CPU65xxxxx (all Versions)
        Premium processors with integrated Ethernet (all Versions)

Exploitation Mechanism

Attackers can exploit this vulnerability by sending a specifically crafted command over Modbus to trigger a Denial of Service condition.

Mitigation and Prevention

Protecting systems from CVE-2020-7477 requires immediate actions and long-term security practices.

Immediate Steps to Take

        Apply security patches provided by Schneider Electric.
        Implement network segmentation to limit the impact of potential attacks.
        Monitor network traffic for any suspicious activity.

Long-Term Security Practices

        Regularly update and patch all software and firmware.
        Conduct security assessments and penetration testing on industrial control systems.
        Educate personnel on cybersecurity best practices.

Patching and Updates

Schneider Electric may release patches or updates to address the vulnerability. Stay informed about security advisories and apply patches promptly.