Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2020-7542 : Vulnerability Insights and Analysis

Discover the CWE-754 vulnerability in Modicon M580, M340, Quantum & Premium controllers by Schneider Electric, potentially leading to denial of service. Learn about impacts and mitigation steps.

A CWE-754 vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium, potentially leading to denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.

Understanding CVE-2020-7542

This CVE involves an Improper Check for Unusual or Exceptional Conditions vulnerability in Schneider Electric's Modicon devices.

What is CVE-2020-7542?

The vulnerability in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium could be exploited through a specially crafted Read Physical Memory request over Modbus, resulting in denial of service.

The Impact of CVE-2020-7542

If exploited, this vulnerability could lead to a denial of service condition on the affected devices, potentially disrupting critical operations.

Technical Details of CVE-2020-7542

This section provides more technical insights into the vulnerability.

Vulnerability Description

The CWE-754 vulnerability arises from an improper check for unusual or exceptional conditions in the affected Schneider Electric Modicon devices.

Affected Systems and Versions

        Products: Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium
        Versions: Refer to security notifications for the specific affected versions.

Exploitation Mechanism

The vulnerability can be exploited by sending a specially crafted Read Physical Memory request over Modbus to the controller, triggering a denial of service.

Mitigation and Prevention

Protecting systems from CVE-2020-7542 is crucial for maintaining security.

Immediate Steps to Take

        Apply security patches provided by Schneider Electric promptly.
        Implement network segmentation to limit exposure to potential attacks.
        Monitor network traffic for any suspicious activity.

Long-Term Security Practices

        Regularly update and patch all software and firmware on the affected devices.
        Conduct security assessments and penetration testing to identify and address vulnerabilities.

Patching and Updates

        Stay informed about security advisories and updates from Schneider Electric.
        Follow best practices for secure Modbus communication to prevent exploitation of this vulnerability.