Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2020-7574 : Exploit Details and Defense Strategies

Learn about CVE-2020-7574 affecting Siemens Climatix POL908 and POL909 devices. Discover the impact, affected versions, and mitigation steps for this XSS vulnerability.

A vulnerability has been identified in Climatix POL908 (BACnet/IP module) and Climatix POL909 (AWM module) that could allow an attacker to inject arbitrary JavaScript code, compromising the confidentiality and integrity of users' web sessions.

Understanding CVE-2020-7574

This CVE involves a persistent cross-site scripting (XSS) vulnerability in the "Server Config" web interface of the affected devices.

What is CVE-2020-7574?

        The vulnerability affects Climatix POL908 (BACnet/IP module) and Climatix POL909 (AWM module).
        It allows an attacker to inject malicious JavaScript code.
        Successful exploitation does not require system privileges.
        Attackers with network access to the affected system can compromise user sessions.

The Impact of CVE-2020-7574

        Confidentiality and integrity of users' web sessions can be compromised.

Technical Details of CVE-2020-7574

This section provides more technical insights into the vulnerability.

Vulnerability Description

        Type: Cross-site Scripting (XSS)
        CWE ID: CWE-79
        Description: Improper Neutralization of Input During Web Page Generation

Affected Systems and Versions

        Climatix POL908 (BACnet/IP module): All versions
        Climatix POL909 (AWM module): All versions < V11.32

Exploitation Mechanism

        Attackers inject arbitrary JavaScript code through the "Server Config" web interface.
        The injected code can be executed by another user, potentially privileged.

Mitigation and Prevention

Protecting systems from CVE-2020-7574 is crucial for maintaining security.

Immediate Steps to Take

        Apply vendor-supplied patches promptly.
        Restrict network access to vulnerable devices.
        Monitor for any suspicious activities on the affected systems.

Long-Term Security Practices

        Regularly update and patch all software and firmware.
        Conduct security assessments and penetration testing.
        Educate users on safe browsing practices and awareness of XSS attacks.

Patching and Updates

        Siemens may provide patches to address the vulnerability.
        Regularly check for updates and apply them as soon as they are available.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now