Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2021-33000 : What You Need to Know

Learn about CVE-2021-33000 affecting WebAccess HMI Designer versions 2.1.9.95 and earlier. Take immediate steps to update the software and prevent arbitrary code execution.

A heap-based buffer overflow vulnerability, identified as CVE-2021-33000, affects WebAccess HMI Designer versions 2.1.9.95 and prior. This flaw could be exploited by an attacker to execute arbitrary code after tricking a user into opening a malicious project file.

Understanding CVE-2021-33000

This section will detail the nature of the vulnerability and its impact.

What is CVE-2021-33000?

The CVE-2021-33000 vulnerability involves parsing a specially crafted project file on WebAccess HMI Designer, leading to a heap-based buffer overflow. This could grant an attacker the ability to execute arbitrary code on the target system, with the condition that the victim interacts with the compromised software.

The Impact of CVE-2021-33000

The impact of this vulnerability is severe as it allows attackers to potentially take control of the affected system and execute malicious code, compromising the confidentiality, integrity, and availability of the targeted device or network.

Technical Details of CVE-2021-33000

This section will provide deeper insights into the technical aspects of the vulnerability.

Vulnerability Description

The vulnerability arises due to a lack of proper input validation when processing project files in versions 2.1.9.95 and earlier of WebAccess HMI Designer, enabling the attacker to overrun the buffer and inject malicious code into the memory space.

Affected Systems and Versions

WebAccess HMI Designer versions 2.1.9.95 and prior are confirmed to be impacted by the CVE-2021-33000 vulnerability. Users of these versions are urged to take immediate action to mitigate the risk.

Exploitation Mechanism

To exploit CVE-2021-33000, an adversary needs to craft a malicious project file and entice a user of the vulnerable WebAccess HMI Designer into opening the file. Once executed, the attacker can achieve arbitrary code execution within the context of the application.

Mitigation and Prevention

In this section, we will discuss the necessary mitigation strategies to safeguard systems from this vulnerability.

Immediate Steps to Take

Users are strongly advised to update their WebAccess HMI Designer software to a patched version that addresses the CVE-2021-33000 vulnerability. Furthermore, exercising caution when opening project files from untrusted sources is crucial to prevent attacks.

Long-Term Security Practices

Implementing secure coding practices, conducting regular security assessments, and staying informed about potential vulnerabilities in software are essential components of maintaining long-term security resilience.

Patching and Updates

Regularly checking for and applying software updates and patches provided by the vendor is critical to addressing known vulnerabilities and enhancing the overall security posture of the WebAccess HMI Designer software.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now