CVE-2021-44007 : Vulnerability Insights and Analysis

Learn about CVE-2021-44007, a vulnerability in JT2Go and Teamcenter Visualization software versions < V13.2.0.5 that allows attackers to trigger denial-of-service through specially crafted TIFF files. Find mitigation steps here.

A vulnerability has been identified in JT2Go and Teamcenter Visualization software where specially crafted TIFF files can lead to a denial-of-service condition.

Understanding CVE-2021-44007

This CVE identifies a specific vulnerability present in Siemens' JT2Go and Teamcenter Visualization software.

What is CVE-2021-44007?

The vulnerability exists in the Tiff_Loader.dll component due to an off-by-one error in the heap during the parsing of certain TIFF files. This flaw could be exploited by an attacker to trigger a denial-of-service situation.

The Impact of CVE-2021-44007

The vulnerability could potentially allow an attacker to cause denial-of-service conditions on systems running the affected software, posing a risk to system availability.

Technical Details of CVE-2021-44007

This section covers detailed technical information about the vulnerability.

Vulnerability Description

The Tiff_Loader.dll in JT2Go and Teamcenter Visualization software versions prior to V13.2.0.5 contains an off-by-one error in the heap while processing malicious TIFF files.

Affected Systems and Versions

        Product: JT2Go
              Vendor: Siemens
              Versions Affected: All versions prior to V13.2.0.5
        Product: Teamcenter Visualization
              Vendor: Siemens
              Versions Affected: All versions prior to V13.2.0.5

Exploitation Mechanism

Attackers can exploit this vulnerability by providing specially crafted TIFF files, triggering the off-by-one error in the Tiff_Loader.dll component and potentially leading to a denial-of-service condition.

Mitigation and Prevention

Mitigation strategies to address CVE-2021-44007.

Immediate Steps to Take

        Apply patches or updates provided by Siemens to address the vulnerability.
        Monitor security advisories from Siemens for any further instructions.

Long-Term Security Practices

        Regularly update software and apply security patches promptly.
        Conduct regular security assessments and audits to identify and address vulnerabilities proactively.

Patching and Updates

        Install the latest version of the software (V13.2.0.5 or higher) to prevent exploitation of this vulnerability.