Learn about CVE-2022-1229 impacting Bentley MicroStation CONNECT 10.16.2.034. Remote attackers can execute code via crafted IFC files, necessitating user interaction for exploitation.
This CVE refers to a vulnerability in Bentley MicroStation CONNECT 10.16.2.034 that allows remote attackers to execute arbitrary code. User interaction is necessary for exploitation through visiting a malicious page or opening a malicious file. The vulnerability lies in the parsing of IFC files, where crafted data can trigger a buffer overflow, enabling code execution.
Understanding CVE-2022-1229
This section delves into the nature of the CVE and its impact on affected systems.
What is CVE-2022-1229?
CVE-2022-1229 exposes a flaw in Bentley MicroStation CONNECT 10.16.2.034, enabling attackers to inject and execute malicious code by manipulating IFC files. The exploit requires user interaction, such as visiting a compromised webpage or opening a corrupted file.
The Impact of CVE-2022-1229
The vulnerability poses a high risk as it allows remote threat actors to compromise the security of systems running the affected Bentley software, potentially leading to unauthorized code execution and data breaches.
Technical Details of CVE-2022-1229
This section provides detailed technical insights into the vulnerability.
Vulnerability Description
The vulnerability arises from improper handling of IFC files in Bentley MicroStation CONNECT 10.16.2.034, leading to a buffer overflow that can be manipulated by attackers to execute arbitrary code within the context of the affected process.
Affected Systems and Versions
Bentley MicroStation CONNECT versions up to and including 10.16.2.034 are susceptible to this vulnerability, putting systems utilizing these versions at risk of exploitation.
Exploitation Mechanism
By crafting malicious data within an IFC file, threat actors can trigger a buffer overflow in Bentley MicroStation CONNECT, leading to the execution of arbitrary code with high impact on confidentiality, integrity, and availability.
Mitigation and Prevention
This section outlines steps to mitigate and prevent exploitation of CVE-2022-1229.
Immediate Steps to Take
Users are advised to update Bentley MicroStation CONNECT to a non-vulnerable version, restrict access to vulnerable systems, and educate users on avoiding suspicious files or links to mitigate the risk of exploitation.
Long-Term Security Practices
Implementing secure coding practices, conducting regular security assessments, and staying informed about software vulnerabilities are essential for long-term security.
Patching and Updates
Regularly applying security patches provided by Bentley and keeping software up to date is crucial in safeguarding against known vulnerabilities and ensuring the overall security of systems.