Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2022-22732 : Vulnerability Insights and Analysis

Discover the impact of CVE-2022-22732, a CWE-668 vulnerability in Schneider Electric's EcoStruxure Power Commission software. Learn about affected versions, mitigation strategies, and prevention measures.

A CWE-668 vulnerability has been identified in Schneider Electric's EcoStruxure Power Commission software, allowing remote domains to access server resources. This article provides insights into the impact, technical details, and mitigation strategies for CVE-2022-22732.

Understanding CVE-2022-22732

This section delves into the specifics of CVE-2022-22732, shedding light on the vulnerability's nature and implications.

What is CVE-2022-22732?

The CVE-2022-22732 vulnerability refers to a CWE-668: Exposure of Resource to Wrong Sphere issue in EcoStruxure Power Commission software. It enables remote domains to interact with server resources through unauthorized fetch requests.

The Impact of CVE-2022-22732

The exploitation of CVE-2022-22732 could result in unauthorized access to sensitive data by remote entities. Attackers leveraging this vulnerability may compromise the confidentiality and integrity of the server's resources.

Technical Details of CVE-2022-22732

This section outlines the technical aspects of CVE-2022-22732, including the vulnerability description, affected systems, and exploitation mechanisms.

Vulnerability Description

The vulnerability allows all remote domains to access resources provided by the server via fetch requests, leading to potential data exposure and unauthorized access.

Affected Systems and Versions

Schneider Electric's EcoStruxure Power Commission software versions prior to V2.22 are affected by CVE-2022-22732. Users utilizing these versions are at risk of exploitation.

Exploitation Mechanism

Attackers can exploit this vulnerability by sending malicious fetch requests from third-party or unauthorized sites, enabling them to access server resources that should be restricted.

Mitigation and Prevention

To address CVE-2022-22732, users should take immediate steps to secure their systems and implement long-term security practices to prevent similar vulnerabilities in the future.

Immediate Steps to Take

Users should update EcoStruxure Power Commission software to version V2.22 or higher to mitigate the CVE-2022-22732 vulnerability. Additionally, monitoring network activity for suspicious fetch requests is recommended.

Long-Term Security Practices

Implementing access controls, regular security audits, and employee training on phishing and social engineering attacks can enhance the overall security posture and reduce the risk of future vulnerabilities.

Patching and Updates

Regularly applying security patches and updates issued by Schneider Electric is crucial to safeguard against known vulnerabilities like CVE-2022-22732.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now