Cloud Defense Logo

Products

Solutions

Company

CVE-2022-25622 : Vulnerability Insights and Analysis

Learn about CVE-2022-25622, a vulnerability in Siemens products affecting PROFINET stacks. Understand the impact, affected systems, mitigation steps, and more.

A vulnerability has been identified in various Siemens products which could lead to a denial-of-service condition. Here's what you need to know about CVE-2022-25622.

Understanding CVE-2022-25622

This CVE pertains to a vulnerability in multiple Siemens products that could potentially be exploited by an attacker to cause a denial-of-service condition on the affected devices.

What is CVE-2022-25622?

The vulnerability in the PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments with a minimum TCP-Header length less than defined. This could be exploited by a malicious actor to disrupt TCP services on the impacted devices.

The Impact of CVE-2022-25622

The vulnerability poses a moderate risk with a CVSS v3.1 base score of 5.3 out of 10. An attacker could exploit this issue to trigger a denial-of-service condition on the affected devices, impacting the availability of TCP services.

Technical Details of CVE-2022-25622

Here are the specific technical details related to the CVE-2022-25622 vulnerability:

Vulnerability Description

The vulnerability stems from the improper handling of internal resources for TCP segments with insufficient TCP-Header length by the PROFINET (PNIO) stack, leading to a denial-of-service risk.

Affected Systems and Versions

Several Siemens products across different families and versions are affected by this vulnerability. These include SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200pro CPUs, SIMATIC ET 200S CPUs, SINAMICS drives, SIMATIC S7 CPUs, and more.

Exploitation Mechanism

An attacker can exploit this vulnerability by crafting and sending specially designed TCP segments to the affected devices, causing a denial-of-service condition for TCP services.

Mitigation and Prevention

To address CVE-2022-25622 and reduce the associated risks, consider the following mitigation steps:

Immediate Steps to Take

        Siemens advises users to apply the necessary security patches provided by the company to address the vulnerability.
        Implement network security best practices and restrict access to vulnerable devices.

Long-Term Security Practices

        Regularly monitor vendor security advisories and updates for any new information regarding the vulnerability.
        Conduct thorough security assessments and penetration testing to identify and address any potential vulnerabilities.

Patching and Updates

        Ensure timely installation of software updates and security patches released by Siemens to mitigate the CVE-2022-25622 vulnerability.