Discover the details of CVE-2022-25752, a vulnerability in various SCALANCE devices by Siemens that allows remote attackers to hijack sessions. Learn about the impact, affected systems, and mitigation steps.
A vulnerability has been identified in multiple SCALANCE devices by Siemens that could allow an unauthenticated remote attacker to hijack existing sessions due to insecure handling of session IDs and nonces.
Understanding CVE-2022-25752
This CVE relates to a security flaw in various SCALANCE devices from Siemens that could lead to session hijacking by exploiting how the webserver generates session IDs and nonces insecurely.
What is CVE-2022-25752?
The vulnerability in SCALANCE X302-7 EEC, X304-2FE, X306-1LD FE, X307 series, X308 series, X310 series, X320 series, X408-2, XR324 series, and SIPLUS NET SCALANCE X308-2 devices occurs due to the webserver's insecure session ID and nonce calculation, enabling attackers to brute-force session IDs and take over sessions.
The Impact of CVE-2022-25752
This vulnerability poses a significant risk as an unauthenticated attacker could exploit it to compromise sessions on the affected SCALANCE devices, potentially leading to unauthorized access and control of critical systems.
Technical Details of CVE-2022-25752
The vulnerability is classified under CWE-330, indicating the use of insufficiently random values that can be exploited to compromise session security on the impacted SCALANCE devices.
Vulnerability Description
The flaw arises from the insecure manner in which the webserver of the affected devices generates session IDs and nonces, creating an opportunity for remote attackers to perform session hijacking attacks.
Affected Systems and Versions
All versions of the SCALANCE X302-7 EEC, X304-2FE, X306-1LD FE, X307 series, X308 series, X310 series, X320 series, X408-2, XR324 series, and SIPLUS NET SCALANCE X308-2 devices prior to V4.1.4 are impacted by this vulnerability.
Exploitation Mechanism
By leveraging the insecure session ID and nonce calculation method of the webserver on the affected devices, attackers can conduct brute-force attacks to gain unauthorized access to sessions.
Mitigation and Prevention
It is crucial for organizations using the affected SCALANCE devices to take immediate steps to mitigate the risk and implement long-term security measures to prevent such vulnerabilities in the future.
Immediate Steps to Take
Organizations should apply patches and updates provided by Siemens to address the vulnerability promptly. Additionally, monitoring network traffic for any suspicious activity can help in early detection of potential attacks.
Long-Term Security Practices
Implementing robust authentication mechanisms, regular security assessments, and keeping systems up to date with the latest security patches are essential practices to enhance the overall security posture and resilience of industrial networks.
Patching and Updates
Siemens has released patches to rectify the vulnerability in the affected SCALANCE devices. System administrators are advised to apply these updates as soon as possible to prevent exploitation and safeguard their industrial control systems.