Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2022-26380 : What You Need to Know

Discover the impact of CVE-2022-26380, a vulnerability in Siemens SCALANCE devices. Learn about affected systems, exploitation risks, and mitigation steps.

A vulnerability has been identified in multiple SCALANCE devices by Siemens. Affected devices do not properly validate a certain SNMP key, making them vulnerable to exploitation.

Understanding CVE-2022-26380

This CVE identifies a security issue in various SCALANCE devices manufactured by Siemens.

What is CVE-2022-26380?

The vulnerability in affected SCALANCE devices allows an attacker to trigger a reboot by exploiting SNMP key validation.

The Impact of CVE-2022-26380

The vulnerability could be exploited by an attacker to disrupt the operation of the affected SCALANCE devices, potentially leading to downtime and operational issues.

Technical Details of CVE-2022-26380

The security flaw lies in the improper validation of a specific SNMP key in the affected SCALANCE devices. An attacker could exploit this weakness to trigger device reboots.

Vulnerability Description

The devices affected by CVE-2022-26380 fail to adequately verify the existence of a particular SNMP key, enabling malicious actors to manipulate it for unintended reboots.

Affected Systems and Versions

All versions of SCALANCE X302-7 EEC, X302-7 EEC (coated), X302-7 EEC (24V), X302-7 EEC (24V, coated), and several other SCALANCE models prior to V4.1.4 are impacted by this vulnerability.

Exploitation Mechanism

By crafting specific SNMP requests to the affected devices with the unvalidated key, an attacker can exploit the vulnerability and cause device reboots.

Mitigation and Prevention

It is crucial for users of the affected SCALANCE devices to take immediate action to prevent potential exploitation and mitigate risks.

Immediate Steps to Take

Users should apply the necessary patches and updates provided by Siemens to address the SNMP key validation issue and enhance device security.

Long-Term Security Practices

Implementing robust network security measures, such as network segmentation and access control, can help mitigate the risk of further vulnerabilities.

Patching and Updates

Regularly check for security advisories from Siemens and promptly apply software updates to protect the SCALANCE devices from known vulnerabilities.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?