Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2022-39156 Explained : Impact and Mitigation

Vulnerability in Siemens' Parasolid & Simcenter Femap software allows code execution. Learn impact, affected versions, and mitigation steps for CVE-2022-39156.

A vulnerability has been identified in multiple versions of Siemens' Parasolid and Simcenter Femap software. The vulnerability could allow an attacker to execute code within the current process by exploiting an out-of-bounds read issue when parsing X_T files.

Understanding CVE-2022-39156

This CVE affects various versions of Parasolid and Simcenter Femap software developed by Siemens.

What is CVE-2022-39156?

The vulnerability found in the affected software versions allows attackers to trigger an out-of-bounds read beyond the end of an allocated buffer during the parsing of X_T files. This can lead to unauthorized code execution in the application's context.

The Impact of CVE-2022-39156

Exploiting this vulnerability could result in unauthorized code execution within the context of the affected application, potentially leading to further system compromise.

Technical Details of CVE-2022-39156

Vulnerability Description

The vulnerability in Parasolid and Simcenter Femap software arises from improper handling of input when processing X_T files, leading to an out-of-bounds read issue beyond the allocated buffer.

Affected Systems and Versions

The following versions of Siemens' software are affected:

        Parasolid V33.1 (All versions < V33.1.262)
        Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263)
        Parasolid V34.0 (All versions < V34.0.252)
        Parasolid V34.1 (All versions < V34.1.242)
        Parasolid V35.0 (All versions < V35.0.161)
        Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164)
        Simcenter Femap V2022.1 (All versions < V2022.1.3)
        Simcenter Femap V2022.2 (All versions < V2022.2.2)

Exploitation Mechanism

Attackers can exploit this vulnerability by crafting malicious X_T files to trigger an out-of-bounds read, potentially leading to code execution within the affected application.

Mitigation and Prevention

Immediate Steps to Take

Users of the affected Siemens software should apply the latest security patches provided by the vendor to mitigate the risk of exploitation. It is crucial to update to non-vulnerable versions as soon as possible.

Long-Term Security Practices

To enhance overall security posture, organizations should implement robust secure coding practices, conduct regular security assessments, and educate developers on secure coding techniques.

Patching and Updates

Stay informed about security advisories from Siemens regarding the availability of patches for the affected software. Regularly update the software to address known vulnerabilities and enhance system security.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now