CVE-2023-22400 involves an Uncontrolled Resource Consumption vulnerability in Juniper Networks Junos OS Evolved, allowing unauthorized access leading to FPC crashes and Denial of Service.
This CVE involves an Uncontrolled Resource Consumption vulnerability in Juniper Networks Junos OS Evolved, allowing an unauthenticated attacker to cause an FPC crash, leading to a Denial of Service (DoS) by executing specific SNMP GET operations or CLI commands.
Understanding CVE-2023-22400
This section delves into the details of CVE-2023-22400, highlighting the impact, technical aspects, and mitigation strategies associated with this vulnerability.
What is CVE-2023-22400?
The CVE-2023-22400 vulnerability specifically affects the PFE management daemon (evo-pfemand) of Juniper Networks Junos OS Evolved, resulting in an FPC crash due to uncontrolled resource consumption. Attackers can trigger this vulnerability through specific SNMP GET operations or CLI commands, leading to Denial of Service (DoS) incidents.
The Impact of CVE-2023-22400
The exploitation of CVE-2023-22400 can result in FPC crashes, exhaustion of resources, and subsequent reboots, causing disruption to network services and availability. It poses a significant threat to systems running affected versions of Junos OS Evolved.
Technical Details of CVE-2023-22400
This section provides a deeper look into the vulnerability, including its description, affected systems and versions, and the exploitation mechanism.
Vulnerability Description
The vulnerability in the evo-pfemand process allows attackers to exhaust GUID resources, leading to FPC crashes. This unethical consumption of resources triggers a DoS condition, impacting system stability and performance.
Affected Systems and Versions
Juniper Networks Junos OS Evolved versions prior to 20.4R3-S3-EVO, 21.1-EVO version 21.1R1-EVO and later, 21.2-EVO versions prior to 21.2R3-S4-EVO, 21.3-EVO version 21.3R1-EVO and later, and 21.4-EVO versions prior to 21.4R2-EVO are susceptible to this vulnerability.
Exploitation Mechanism
By executing specific SNMP GET operations or CLI commands, attackers can trigger the GUID resource leak, causing exhaustion and leading to FPC crashes and reboots. This exploitation can be monitored by observing command output for Guids on affected platforms.
Mitigation and Prevention
In response to CVE-2023-22400, it is essential to implement immediate steps, adopt long-term security practices, and apply necessary patches and updates to mitigate risks effectively.
Immediate Steps to Take
While no specific workarounds are available, restricting network access using access lists or firewall filters to trusted entities can help reduce the risk of exploitation.
Long-Term Security Practices
Maintaining up-to-date security configurations, conducting regular vulnerability assessments, and implementing network segmentation can enhance overall security posture and resilience against similar threats.
Patching and Updates
Juniper Networks has released updated software versions like 20.4R3-S3-EVO, 21.2R3-S4-EVO, 21.4R2-EVO, 22.1R1-EVO, and subsequent releases to address and resolve the CVE-2023-22400 vulnerability. It is crucial for organizations to promptly apply these patches to safeguard their systems against potential exploits.