Find out about the critical CVE-2023-22585 affecting Danfoss AK-EM100 systems, allowing Reflected Cross-Site Scripting. Learn mitigation steps.
This CVE-2023-22585 relates to a vulnerability in the Danfoss AK-EM100 web applications that allows for Reflected Cross-Site Scripting in the title parameter. The issue was discovered by security researchers Jony Schats, Stan Plasmeijer from Hackdefense, and analyzed by Max van der Horst from DIVD.
Understanding CVE-2023-22585
This section delves into the details and implications of the CVE-2023-22585 vulnerability.
What is CVE-2023-22585?
CVE-2023-22585 is a vulnerability found in the Danfoss AK-EM100 web applications that enables Reflected Cross-Site Scripting through the title parameter. This could potentially allow malicious actors to execute arbitrary code in the context of a user's session.
The Impact of CVE-2023-22585
The impact of CVE-2023-22585 is classified as critical with a base score of 9.0, indicating a high severity level. The vulnerability's exploit could lead to a compromise of data confidentiality, data integrity, and service availability, posing a significant risk to affected systems.
Technical Details of CVE-2023-22585
This section provides technical insights into the vulnerability, including its description, affected systems and versions, and exploitation mechanism.
Vulnerability Description
The vulnerability in Danfoss AK-EM100 web applications allows for Reflected Cross-Site Scripting, enabling attackers to inject and execute malicious scripts through the title parameter.
Affected Systems and Versions
The CVE-2023-22585 vulnerability impacts Danfoss AK-EM100 systems with versions lower than 2.2.0.12.
Exploitation Mechanism
Exploiting CVE-2023-22585 involves crafting malicious scripts that are reflected back to users when interacting with the affected web applications, potentially leading to unauthorized actions or data theft.
Mitigation and Prevention
To address CVE-2023-22585, it is crucial to implement immediate steps for mitigation and long-term security practices to prevent similar vulnerabilities in the future.
Immediate Steps to Take
As the Danfoss AK-EM100 has reached End of Life (EOL), the vendor advises phasing out this device to eliminate the risk associated with the vulnerability.
Long-Term Security Practices
Incorporate secure coding practices, perform regular security assessments, and stay updated on software patches and security advisories to mitigate the risk of such vulnerabilities in the long term.
Patching and Updates
Ensure timely application of security patches provided by the vendor and follow best practices for system updates to prevent exploitation of known vulnerabilities like CVE-2023-22585.