Learn about CVE-2023-22805 impacting LS Electric's XBC-DN32U operating system version 01.80. Remote attackers can manipulate read prohibition, affecting data access. Mitigation steps included.
This CVE-2023-22805 was published by the assigner organization ICS-CERT on February 15, 2023. It involves vulnerabilities reported in LS Electric's XBC-DN32U with operating system version 01.80, which allows remote attackers to manipulate the read prohibition feature, potentially locking users out from accessing data on the device.
Understanding CVE-2023-22805
This section will delve into the specifics of CVE-2023-22805, including the vulnerability description, impact, technical details, affected systems, and mitigation steps.
What is CVE-2023-22805?
The vulnerability in LS Electric's XBC-DN32U with operating system version 01.80 lies in its improper access control to the read prohibition feature. This flaw could enable malicious actors to remotely set the feature, thereby restricting legitimate users from reading data on the device.
The Impact of CVE-2023-22805
With a CVSSv3 base score of 6.5, this vulnerability poses a medium-severity risk. Although it does not impact confidentiality or integrity, the availability of the system could be significantly affected. Attack complexity is low, and the vector is through the network.
Technical Details of CVE-2023-22805
Examining the vulnerability from a technical standpoint reveals crucial insights into its nature and potential risks.
Vulnerability Description
The vulnerability allows remote attackers to manipulate the read prohibition feature in LS Electric's XBC-DN32U, leading to denial of service by blocking user access to device data.
Affected Systems and Versions
Specifically, LS Electric's XBC-DN32U running operating system version 01.80 is susceptible to this vulnerability, potentially impacting users of this particular product.
Exploitation Mechanism
The exploitation of this vulnerability occurs remotely, where attackers can exploit the improper access control to manipulate the read prohibition feature.
Mitigation and Prevention
To address CVE-2023-22805, immediate action should be taken to prevent potential exploitation and secure affected systems.
Immediate Steps to Take
Long-Term Security Practices
In the long run, users should stay informed about security updates from the vendor, follow best practices for securing industrial control systems, and maintain a proactive approach to cybersecurity.
Patching and Updates
Regularly check for updates and patches from LS Electric to address vulnerabilities like CVE-2023-22805. Implementing timely updates can help mitigate risks associated with known security flaws.