Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2023-24143 : Security Advisory and Response

Learn about CVE-2023-24143, a severe command injection flaw in TOTOLINK CA300-PoE V6.2c.884, enabling attackers to execute unauthorized commands. Take immediate security measures.

This CVE record involves TOTOLINK CA300-PoE V6.2c.884, which has been found to have a command injection vulnerability via the NetDiagTracertHop parameter in the setNetworkDiag function.

Understanding CVE-2023-24143

This section will provide an overview of the CVE-2023-24143 vulnerability, its impact, technical details, and mitigation strategies.

What is CVE-2023-24143?

CVE-2023-24143 pertains to a command injection vulnerability in TOTOLINK CA300-PoE V6.2c.884, specifically through the NetDiagTracertHop parameter in the setNetworkDiag function. This flaw could potentially allow an attacker to execute arbitrary commands on the affected system.

The Impact of CVE-2023-24143

The impact of this vulnerability is severe as it could enable malicious actors to run unauthorized commands on the vulnerable TOTOLINK CA300-PoE V6.2c.884 devices. This can lead to further compromise of the system's security and potentially result in unauthorized access or data breaches.

Technical Details of CVE-2023-24143

In this section, we will delve into the technical aspects of the CVE-2023-24143 vulnerability, including its description, affected systems, versions, and exploitation mechanism.

Vulnerability Description

The vulnerability in TOTOLINK CA300-PoE V6.2c.884 arises from a command injection flaw present in the NetDiagTracertHop parameter of the setNetworkDiag function. This weakness could be exploited by an attacker to inject and execute arbitrary commands on the affected device.

Affected Systems and Versions

Currently, TOTOLINK CA300-PoE V6.2c.884 has been identified as affected by this vulnerability. It is crucial for users of this particular device version to be aware of the issue and take necessary precautions.

Exploitation Mechanism

The vulnerability can be exploited by sending specifically crafted commands through the NetDiagTracertHop parameter in the setNetworkDiag function, allowing attackers to execute unauthorized commands on the vulnerable device.

Mitigation and Prevention

Mitigating CVE-2023-24143 requires immediate action to minimize the risk of exploitation and ensure the security of the affected systems.

Immediate Steps to Take

Users and administrators are advised to apply security best practices, such as restricting network access, monitoring for suspicious activities, and implementing strong access controls to prevent unauthorized command injections.

Long-Term Security Practices

Implementing regular security assessments, staying updated on security alerts, and conducting thorough security audits can help in reducing the likelihood of such vulnerabilities in the future.

Patching and Updates

It is crucial for users of TOTOLINK CA300-PoE V6.2c.884 to monitor for security advisories from the vendor and promptly apply any patches or updates released to address the command injection vulnerability and enhance the overall security posture of the device.