Cloud Defense Logo

Products

Solutions

Company

CVE-2023-24584 : Exploit Details and Defense Strategies

Learn about CVE-2023-24584, a high-severity buffer overflow vulnerability in Controller 6000 web interface. Mitigation steps and impact details included.

This CVE-2023-24584 involves a buffer overflow vulnerability in the Controller 6000 device's web interface upload feature. The issue affects various versions of the Controller 6000 product, potentially leading to severe consequences.

Understanding CVE-2023-24584

The vulnerability identified as CVE-2023-24584 pertains to a buffer overflow in the Controller 6000 device's web interface upload feature. This flaw can have a significant impact on the security of affected systems.

What is CVE-2023-24584?

The vulnerability CVE-2023-24584 allows threat actors to trigger a buffer overflow via the Controller diagnostic web interface's upload feature. This exploitation may lead to unauthorized access, data manipulation, or system crashes if not addressed promptly.

The Impact of CVE-2023-24584

The impact of CVE-2023-24584 is classified as high severity, with a CVSS base score of 7.5. The confidentiality, integrity, and availability of affected systems are at risk due to this vulnerability.

Technical Details of CVE-2023-24584

The technical details of CVE-2023-24584 provide insight into the vulnerability's nature, affected systems, and the exploitation mechanism.

Vulnerability Description

The vulnerability arises from a buffer overflow within the Controller 6000 device's web interface upload feature. It allows attackers to potentially execute malicious code or disrupt system operations.

Affected Systems and Versions

The affected systems include the Controller 6000 product, specifically versions prior to vCR8.80.230201a, vCR8.70.230201a, vCR8.60.230201b, vCR8.50.230201a, and all versions of vCR8.40 and earlier.

Exploitation Mechanism

Threat actors can exploit this vulnerability by uploading specially crafted files through the diagnostic web interface of the Controller 6000 device. This can lead to unauthorized access or compromise of the system.

Mitigation and Prevention

To address CVE-2023-24584 and mitigate the associated risks, immediate action and long-term security practices are essential.

Immediate Steps to Take

        Ensure dipswitch 1 is turned off on all Controllers.
        Disable the option "Dipswitch 1 controls the diagnostic web interface" in Configuration Client on Controller property pages.
        Avoid using the Controller override "Enable WWW Connections."
        Refer to the Gallagher Command Centre Hardening Guide for detailed instructions on securing the system.

Long-Term Security Practices

Implementing secure coding practices, regular security assessments, and employee training on cybersecurity best practices can enhance the overall security posture of the system and prevent similar vulnerabilities in the future.

Patching and Updates

Stay informed about security advisories and updates from the vendor, Gallagher, regarding patches or fixes for CVE-2023-24584. Promptly apply necessary updates to mitigate the vulnerability and enhance system security.