Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2023-24995 : What You Need to Know

CVE-2023-24995 involves an out-of-bounds write flaw in Siemens Tecnomatix Plant Simulation software, allowing attackers to execute arbitrary code. Learn about impact, mitigation, and prevention.

This CVE-2023-24995 pertains to a vulnerability identified in Tecnomatix Plant Simulation (All versions < V2201.0006) by Siemens.

Understanding CVE-2023-24995

This section will delve into the details of CVE-2023-24995, including its description, impact, technical details, and mitigation strategies.

What is CVE-2023-24995?

CVE-2023-24995 involves an out-of-bounds write vulnerability present in Tecnomatix Plant Simulation software. Specifically, the flaw occurs when parsing a specially crafted SPP file, leading to an out of bounds write past the allocated buffer. This can potentially enable an attacker to execute arbitrary code within the current process context.

The Impact of CVE-2023-24995

The impact of this vulnerability is rated as HIGH, with a CVSS v3.1 base score of 7.8. Exploitation of this flaw could result in unauthorized execution of code, compromising the confidentiality, integrity, and availability of the affected system.

Technical Details of CVE-2023-24995

Now, let's explore the technical aspects of CVE-2023-24995 to understand the vulnerability more comprehensively.

Vulnerability Description

The vulnerability involves an out-of-bounds write issue triggered by parsing a specially crafted SPP file in Tecnomatix Plant Simulation software.

Affected Systems and Versions

The affected product is Siemens' Tecnomatix Plant Simulation, with all versions prior to V2201.0006 being vulnerable to this exploit.

Exploitation Mechanism

By leveraging the out-of-bounds write vulnerability in the SPP file parsing functionality, threat actors can potentially execute malicious code within the current process, leading to unauthorized access and system compromise.

Mitigation and Prevention

Mitigating CVE-2023-24995 is crucial to ensure the security and integrity of systems running Tecnomatix Plant Simulation software.

Immediate Steps to Take

        Organizations should apply security patches provided by Siemens promptly to address the vulnerability.
        It is recommended to restrict access to the affected application until the patch can be applied.

Long-Term Security Practices

        Implement robust security protocols and access controls to prevent unauthorized access to critical systems.
        Conduct regular security assessments and vulnerability scans to identify and remediate potential threats proactively.

Patching and Updates

Ensure that the software is updated to version V2201.0006 or later to mitigate the risk posed by the out-of-bounds write vulnerability in Tecnomatix Plant Simulation.

By following these mitigation strategies and keeping software up to date, organizations can bolster their defenses against potential exploitation of CVE-2023-24995.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now