Learn about CVE-2023-25140 affecting Siemens Parasolid and Solid Edge SE2022. High severity issue enabling code execution through crafted PAR files.
This CVE record pertains to a vulnerability identified in several Siemens applications - Parasolid and Solid Edge SE2022. The vulnerability allows an attacker to execute arbitrary code by exploiting an out-of-bounds read issue in specially crafted PAR files.
Understanding CVE-2023-25140
This section covers the essential aspects of the CVE-2023-25140 vulnerability, including its description, impact, technical details, and mitigation strategies.
What is CVE-2023-25140?
CVE-2023-25140 is a security flaw found in Parasolid V34.0, Parasolid V34.1, Parasolid V35.0, Parasolid V35.1, and Solid Edge SE2022. The vulnerability arises due to an out-of-bounds read past the end of an allocated structure when parsing specific PAR files. This flaw could potentially enable an attacker to execute malicious code within the current process context.
The Impact of CVE-2023-25140
The impact of CVE-2023-25140 is rated as high severity with a base score of 7.8 according to CVSS version 3.1. If exploited, this vulnerability could result in unauthorized code execution, compromising the integrity, confidentiality, and availability of the affected systems.
Technical Details of CVE-2023-25140
In this section, we delve into the technical specifics of CVE-2023-25140, including the vulnerability description, affected systems, and exploitation mechanism.
Vulnerability Description
The vulnerability in Parasolid and Solid Edge SE2022 arises from an out-of-bounds read issue in the parsing of specially crafted PAR files, leading to potential code execution by malicious actors.
Affected Systems and Versions
The impacted systems include Parasolid V34.0, V34.1, V35.0, V35.1, and Solid Edge SE2022, with specific versions detailed in the CVE report.
Exploitation Mechanism
By exploiting the out-of-bounds read vulnerability in the affected Siemens applications, attackers can execute arbitrary code within the context of the current process, posing a significant security risk.
Mitigation and Prevention
This section outlines the necessary steps to mitigate the CVE-2023-25140 vulnerability and protect the impacted systems from potential exploitation.
Immediate Steps to Take
It is crucial for organizations using Parasolid V34.0, V34.1, V35.0, V35.1, and Solid Edge SE2022 to implement security measures promptly. This may include applying patches, implementing security configurations, and monitoring for any signs of exploitation.
Long-Term Security Practices
To enhance overall cybersecurity posture, organizations should prioritize regular security assessments, vulnerability scanning, employee training on secure coding practices, and robust incident response protocols.
Patching and Updates
Siemens, the vendor of the affected applications, may release patches or updates to address the CVE-2023-25140 vulnerability. It is essential for organizations to promptly apply these patches to eliminate the security risk posed by the out-of-bounds read issue in Parasolid and Solid Edge SE2022.