Learn about CVE-2023-25234 affecting Tenda AC500 V2.0.1.9(1307). Discover the impact, mitigation steps, and prevention measures for this vulnerability.
This CVE record was published on February 27, 2023, by MITRE. The vulnerability identified is in the Tenda AC500 V2.0.1.9(1307) device, which is susceptible to a Buffer Overflow in a specific function.
Understanding CVE-2023-25234
The vulnerability in Tenda AC500 V2.0.1.9(1307) can be exploited through a Buffer Overflow in a function called fromAddressNat, using parameters entrys and mitInterface.
What is CVE-2023-25234?
CVE-2023-25234 is a security vulnerability identified in the Tenda AC500 V2.0.1.9(1307) device, which allows for a Buffer Overflow attack in the fromAddressNat function utilizing the parameters entrys and mitInterface.
The Impact of CVE-2023-25234
This vulnerability could potentially allow an attacker to execute arbitrary code on the affected device, leading to unauthorized access, data breaches, or disruption of services.
Technical Details of CVE-2023-25234
The technical aspects of CVE-2023-25234 provide insights into the nature of the vulnerability, the affected systems and versions, as well as the exploitation mechanism.
Vulnerability Description
The Buffer Overflow vulnerability in the Tenda AC500 V2.0.1.9(1307) device occurs in the fromAddressNat function, triggered by the parameters entrys and mitInterface. This could result in a potential security breach.
Affected Systems and Versions
The specific affected vendor, product, and version details are not available at the moment. However, users of the Tenda AC500 V2.0.1.9(1307) device should be aware of this vulnerability.
Exploitation Mechanism
The vulnerability can be exploited by an attacker sending specially crafted input to the affected function, causing a Buffer Overflow condition and potentially leading to remote code execution.
Mitigation and Prevention
In order to mitigate the risks associated with CVE-2023-25234, immediate actions, as well as long-term security practices, should be implemented. Additionally, applying patches and updates is crucial to prevent exploitation of this vulnerability.
Immediate Steps to Take
Users of Tenda AC500 V2.0.1.9(1307) should update their firmware to the latest version provided by the vendor. Implementing network security measures to restrict unauthorized access and monitoring for any unusual activity is recommended.
Long-Term Security Practices
Maintaining cybersecurity hygiene practices such as regular security audits, employee training on cybersecurity best practices, and implementing defense-in-depth strategies can enhance overall security posture and prevent future vulnerabilities.
Patching and Updates
Vendor-supplied patches and updates should be applied promptly to address and mitigate the CVE-2023-25234 vulnerability. Regularly checking for security advisories from the vendor and staying updated on cybersecurity news can help in timely patch management.