Cloud Defense Logo

Products

Solutions

Company

Book A Live Demo

CVE-2023-37437 : Vulnerability Insights and Analysis

Learn about CVE-2023-37437, multiple SQL injection vulnerabilities in EdgeConnect SD-WAN Orchestrator's web-based management interface, posing high risks. Find out affected systems, exploitation, and mitigation steps.

This article provides detailed information about CVE-2023-37437, which involves authenticated SQL injection vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator.

Understanding CVE-2023-37437

CVE-2023-37437 highlights multiple vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator, allowing an authenticated remote attacker to perform SQL injection attacks, potentially leading to exposure and corruption of sensitive data.

What is CVE-2023-37437?

Multiple vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could enable an authenticated remote attacker to conduct SQL injection attacks, compromising sensitive information in the database.

The Impact of CVE-2023-37437

The vulnerabilities could result in the exposure and corruption of sensitive data controlled by the EdgeConnect SD-WAN Orchestrator host, posing a high risk to confidentiality and integrity.

Technical Details of CVE-2023-37437

This section delves into the specific technical aspects of CVE-2023-37437.

Vulnerability Description

The vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator facilitate SQL injection attacks by authenticated remote attackers, potentially allowing unauthorized access to confidential data.

Affected Systems and Versions

The vulnerability affects EdgeConnect SD-WAN Orchestrator versions up to 9.3.0, 9.2.x, and 9.1.x from Hewlett Packard Enterprise (HPE).

Exploitation Mechanism

By exploiting these vulnerabilities, an attacker can manipulate and extract sensitive information from the database, leading to data exposure and potential corruption.

Mitigation and Prevention

To address CVE-2023-37437, immediate steps and long-term security practices are crucial.

Immediate Steps to Take

Organizations should apply security patches promptly, restrict access to vulnerable systems, and monitor database activities for suspicious behavior.

Long-Term Security Practices

Implementing secure coding practices, conducting regular security audits, and educating users on SQL injection risks can enhance overall cybersecurity.

Patching and Updates

Installing the latest patches provided by Hewlett Packard Enterprise (HPE) is essential to mitigate the SQL injection vulnerabilities in EdgeConnect SD-WAN Orchestrator.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now