Discover the impact of CVE-2023-39945, a high-severity vulnerability in eProsima Fast DDS versions prior to 2.11.0, 2.10.2, 2.9.2, and 2.6.5. Learn how to mitigate the risk and secure your systems.
A vulnerability has been discovered in the eProsima Fast DDS software, affecting versions prior to 2.11.0, 2.10.2, 2.9.2, and 2.6.5. This vulnerability arises from a flaw in handling serialized data in a data submessage, leading to an unhandled exception that can cause the software to crash.
Understanding CVE-2023-39945
This section provides an overview of the CVE-2023-39945 vulnerability.
What is CVE-2023-39945?
The CVE-2023-39945 vulnerability in eProsima Fast DDS is caused by malformed serialized data in a data submessage that triggers an unhandled
BadParamException
in fastcdr. This exception can result in the crashing of the Fast-DDS software when processing the data.
The Impact of CVE-2023-39945
With a CVSS base score of 8.2, this high-severity vulnerability can lead to service disruptions and denial of service (DoS) attacks. Attackers could potentially exploit this flaw to cause instability and crashes in systems running affected versions of the eProsima Fast DDS software.
Technical Details of CVE-2023-39945
This section delves deeper into the technical aspects of the CVE-2023-39945 vulnerability.
Vulnerability Description
The vulnerability arises from a flaw in processing serialized data in a data submessage, causing an unhandled exception that can crash the Fast DDS software versions prior to 2.11.0, 2.10.2, 2.9.2, and 2.6.5.
Affected Systems and Versions
The eProsima Fast DDS versions impacted by this vulnerability include those prior to 2.11.0, 2.10.2, 2.9.2, and 2.6.5. Users of these versions are advised to take immediate action to mitigate the risk.
Exploitation Mechanism
Attackers can exploit this vulnerability by crafting and sending specially designed data submessages to the PDP port, triggering the unhandled
BadParamException
in fastcdr and potentially crashing the Fast DDS software.
Mitigation and Prevention
In this section, we discuss the steps to mitigate and prevent exploitation of CVE-2023-39945.
Immediate Steps to Take
Users of eProsima Fast DDS should update their software to versions 2.11.0, 2.10.2, 2.9.2, or 2.6.5, which contain patches to address this vulnerability. It is crucial to apply these updates promptly to safeguard systems from potential attacks.
Long-Term Security Practices
Implementing secure coding practices and regularly updating software are essential for enhancing the overall security posture of systems. Continuous monitoring and timely patching of vulnerabilities can help prevent exploitation and mitigate risks.
Patching and Updates
Staying informed about security advisories and promptly applying patches released by software vendors are crucial steps in maintaining the security and integrity of software systems.