CVE-2023-4291 Explained : Impact and Mitigation

Learn about CVE-2023-4291, a critical vulnerability in Frauscher FDS101 devices allowing for remote code execution without authentication. Mitigation steps included.

This CVE-2023-4291 article provides detailed information about a critical vulnerability impacting Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi devices.

Understanding CVE-2023-4291

This section will delve into the specifics of CVE-2023-4291, including its impact, technical details, affected systems, and mitigation strategies.

What is CVE-2023-4291?

The CVE-2023-4291 vulnerability affects Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi devices, specifically version 1.4.24 and all previous versions. It allows for remote code execution (RCE) through manipulated parameters of the web interface without authentication, potentially leading to a complete compromise of the FDS101 device.

The Impact of CVE-2023-4291

With a CVSS v3.1 base score of 9.8 out of 10, this vulnerability is classified as critical. It poses a high risk in terms of confidentiality, integrity, and availability of the affected systems. The attack complexity is low, and no privileges are required for exploitation, making it a severe security concern.

Technical Details of CVE-2023-4291

In this section, we will explore the vulnerability description, affected systems and versions, as well as the exploitation mechanism of CVE-2023-4291.

Vulnerability Description

The CVE-2023-4291 vulnerability in Frauscher FDS101 for FAdC/FAdCi allows threat actors to execute arbitrary code on the device by manipulating web interface parameters without the need for authentication.

Affected Systems and Versions

Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi devices running version 1.4.24 and all prior versions are susceptible to the CVE-2023-4291 vulnerability.

Exploitation Mechanism

Exploiting CVE-2023-4291 involves manipulating parameters of the web interface without authentication, enabling attackers to execute malicious code remotely on the FDS101 device.

Mitigation and Prevention

To safeguard against the risks associated with CVE-2023-4291, immediate actions should be taken followed by implementing long-term security practices and applying necessary patches and updates.

Immediate Steps to Take

        Ensure that the affected Frauscher Sensortechnik GmbH FDS101 devices are isolated from untrusted networks.
        Monitor network traffic for any signs of exploitation attempts.
        Contact Frauscher for guidance on mitigating the vulnerability and securing the devices.

Long-Term Security Practices

        Regularly update and patch the firmware of Frauscher FDS101 devices to address known vulnerabilities.
        Implement network segmentation to limit the exposure of critical devices to potential threats.
        Conduct periodic security audits and assessments to identify and remediate security gaps.

Patching and Updates

Stay informed about security advisories from Frauscher Sensortechnik GmbH and promptly apply any patches or updates released to address CVE-2023-4291 and other vulnerabilities.