CVE-2023-4485 : What You Need to Know

Critical CVE-2023-4485 in ARDEREG's Sistema SCADA Central versions 2.203 and earlier enables unauthenticated attackers to carry out blind SQL injections, risking data leaks and process disruption.

This CVE-2023-4485 article provides insights into a critical vulnerability impacting ARDEREG's Sistema SCADA Central versions 2.203 and prior, potentially leading to unauthorized access, data leakage, or disruption of critical industrial processes.

Understanding CVE-2023-4485

CVE-2023-4485 involves an unauthenticated blind SQL injection vulnerability in the login page of ARDEREG's Sistema SCADA Central versions 2.203 and earlier. The vulnerability could allow attackers to manipulate SQL queries through the login page, posing severe security risks.

What is CVE-2023-4485?

The CVE-2023-4485 vulnerability in ARDEREG's Sistema SCADA Central versions 2.203 and prior allows attackers to exploit an unauthenticated blind SQL injection flaw, enabling them to extract sensitive information or execute unauthorized actions in the database.

The Impact of CVE-2023-4485

The impact of CVE-2023-4485 is classified as critical, with a CVSS base score of 9.8. Attackers can potentially achieve unauthorized access, data leakage, or disrupt industrial processes due to the high availability, confidentiality, and integrity impact.

Technical Details of CVE-2023-4485

This section delves deeper into the technical aspects of the vulnerability, including its description, affected systems, versions, and exploitation mechanism.

Vulnerability Description

The vulnerability arises from an unauthenticated blind SQL injection in the login page of ARDEREG's Sistema SCADA Central versions 2.203 and earlier, allowing attackers to execute arbitrary SQL queries, compromising system integrity and confidentiality.

Affected Systems and Versions

ARDEREG's Sistema SCADA Central versions 2.203 and prior are affected by this vulnerability, making them susceptible to exploitation through the login page's SQL injection flaw.

Exploitation Mechanism

Attackers can exploit the unauthenticated blind SQL injection vulnerability in ARDEREG's Sistema SCADA Central by manipulating the application's SQL query logic, potentially leading to unauthorized database access and data manipulation.

Mitigation and Prevention

To mitigate the risks associated with CVE-2023-4485, immediate steps should be taken along with implementing long-term security practices and applying necessary patches and updates.

Immediate Steps to Take

        Conduct regular security awareness and training sessions to educate personnel on secure coding practices and SQL injection vulnerabilities.
        Perform routine security assessments, including penetration testing and code reviews, to identify and address vulnerabilities.
        Develop and maintain an incident response plan tailored for addressing security incidents related to SQL injection.

Long-Term Security Practices

        Ensure vendors and suppliers adhere to secure coding practices and security standards.
        Implement network segmentation to isolate the SCADA system and reduce the attack surface.
        Regularly evaluate and monitor security practices to mitigate vulnerabilities in the supply chain.

Patching and Updates

ARDEREG is aware of the issue and provides workarounds to reduce the risk associated with CVE-2023-4485. Contact ARDEREG for more information on mitigating the vulnerability.

By following these mitigation strategies and best practices, organizations can enhance their security posture and protect their SCADA systems from potential exploitation of CVE-2023-4485.