Cloud Defense Logo

Products

Solutions

Company

CVE-2023-46156 Explained : Impact and Mitigation

Learn about CVE-2023-46156 affecting Siemens devices, allowing attackers to exploit a denial of service vulnerability in port 102/tcp. Understand the impact, affected systems, and mitigation strategies.

A denial of service vulnerability has been identified in Siemens devices due to improper handling of specially crafted packets. This article provides an overview of CVE-2023-46156, its impact, technical details, and mitigation strategies.

Understanding CVE-2023-46156

Affected devices improperly handle specially crafted packets sent to port 102/tcp, leading to a denial of service condition that requires a restart to restore normal operations.

What is CVE-2023-46156?

The vulnerability identified as CVE-2023-46156 affects Siemens devices and allows attackers to exploit the flaw by sending specially crafted packets to port 102/tcp, resulting in a denial of service condition.

The Impact of CVE-2023-46156

The impact of this vulnerability is significant as it can disrupt the normal operations of affected Siemens devices, requiring a restart to recover from the denial of service condition.

Technical Details of CVE-2023-46156

This section outlines the vulnerability description, affected systems and versions, and the exploitation mechanism.

Vulnerability Description

The vulnerability arises from the improper handling of specially crafted packets sent to port 102/tcp on Siemens devices, allowing attackers to create a denial of service condition.

Affected Systems and Versions

Siemens devices affected by CVE-2023-46156 include SIMATIC Drive Controller CPU 1504D TF, SIMATIC Drive Controller CPU 1507D TF, SIMATIC ET 200SP Open Controller CPU 1515SP PC2, and various SIMATIC S7-1500 CPU models.

Exploitation Mechanism

Attackers exploit this vulnerability by sending specially crafted packets to port 102/tcp on affected Siemens devices, triggering a denial of service condition.

Mitigation and Prevention

This section provides guidance on immediate steps to take, long-term security practices, and the importance of patching and updates.

Immediate Steps to Take

It is recommended to apply vendor patches, restrict network access to vulnerable devices, and monitor network traffic for signs of exploitation.

Long-Term Security Practices

Implementing network segmentation, regular security assessments, and security awareness training can enhance overall cybersecurity posture and prevent such vulnerabilities.

Patching and Updates

Stay up to date with official security advisories from Siemens and promptly apply patches or updates to fix the vulnerability and protect against potential exploitation.

Popular CVEs

CVE Id

Published Date

Is your System Free of Underlying Vulnerabilities?
Find Out Now