CVE-2023-47279 : Exploit Details and Defense Strategies

Learn about CVE-2023-47279, a high-severity vulnerability in Delta Electronics' InfraSuite Device Master software v.1.0.7, allowing attackers to disclose user information and obtain plaintext credentials.

A detailed analysis of the vulnerability in Delta Electronics' InfraSuite Device Master software version 1.0.7.

Understanding CVE-2023-47279

This vulnerability in the InfraSuite Device Master software allows unauthenticated attackers to disclose user information, obtain plaintext credentials, or perform NTLM relaying through a single UDP packet.

What is CVE-2023-47279?

In Delta Electronics InfraSuite Device Master v.1.0.7, there exists a vulnerability that enables an unauthenticated attacker to disclose user information, obtain plaintext credentials, or perform NTLM relaying.

The Impact of CVE-2023-47279

The CVE-2023-47279 vulnerability poses a high-severity risk with a CVSS base score of 7.5, allowing attackers to compromise confidentiality by accessing sensitive user information.

Technical Details of CVE-2023-47279

This section provides an in-depth look at the specifics of the CVE-2023-47279 vulnerability.

Vulnerability Description

The vulnerability in Delta Electronics InfraSuite Device Master v.1.0.7 allows unauthenticated attackers to exploit a path traversal vulnerability, potentially leading to unauthorized access to user information.

Affected Systems and Versions

The affected product is the InfraSuite Device Master software by Delta Electronics with versions less than or equal to 1.0.7.

Exploitation Mechanism

Attackers can leverage this vulnerability by sending a single UDP packet to the target system, enabling them to retrieve sensitive user data and credentials.

Mitigation and Prevention

Protecting your systems from the CVE-2023-47279 vulnerability is crucial for maintaining security and safeguarding sensitive information.

Immediate Steps to Take

Immediately update the InfraSuite Device Master software to version 1.0.10 or later as recommended by Delta Electronics to mitigate the vulnerability.

Long-Term Security Practices

Ensure regular security updates and patches are applied to all software components to prevent potential exploitation of known vulnerabilities.

Patching and Updates

Stay proactive in applying security patches and updates provided by software vendors to address newly discovered vulnerabilities and enhance system security.